Skip to content

ayasystems/PowerMaxEsp8266

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

59 Commits
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

PowerMaxEsp8266

PowerMax gateway ESP8266

image

Thank to irekzielinski to make the library -> https://github.com/irekzielinski/PowerMaxAlarm

This sketch provide mqtt comunication to Visonic PowerMax Alarms

Added WifiManager to setup wifi and mqtt connection. MQTT credentials can also be changed at any time via the web UI at http://<ESP-IP>/mqttconfig without reflashing.

Supports Home Assistant MQTT Auto-Discovery: alarm panel and all enrolled sensors appear automatically in HA once the panel config is downloaded (~30 s after boot).

Into folder libraries you can find the used libraries to compile

POWERMAX PINOUT

Web

OUTPUT TOPICS

powermax/stat

Send info about alarm status (sending info each minute or when event occurs)

Example

  • {"stat":"0","stat_str":"Disarmed","lastCom":0,"panelType":"2","panelTypeStr":"PowerMax Pro","panelModelType":"5","alarmState":"0","alarmStateStr":"None","uptime":3600,"freeHeap":28000,"wifiRSSI":-65}
  • {"stat":"1","stat_str":"Exit Delay","lastCom":3,"panelType":"2","panelTypeStr":"PowerMax Pro","panelModelType":"5","alarmState":"0","alarmStateStr":"None","uptime":3600,"freeHeap":28000,"wifiRSSI":-65}

powermax/flags

Send info about alarm status (sending info each minute or when event occurs)

  • {"flags":"39","flags_ready":true,"flags_alertInMemory":true,"flags_trouble":true,"flags_bypasOn":false,"flags_last10sec":false,"flags_zoneEvent":true,"flags_armDisarmEvent":false,"flags_alarmEvent":false}

  • {"flags":"69","flags_ready":true,"flags_alertInMemory":false,"flags_trouble":true,"flags_bypasOn":false,"flags_last10sec":false,"flags_zoneEvent":false,"flags_armDisarmEvent":true,"flags_alarmEvent":false}

powermax/zone

Send one topic for each sensor (sending info each minute or when event occurs)

  • {"zoneId":1,"zoneName":"Puerta principal","zoneType":4,"zoneTypeStr":"Delay 1","sensorId":149,"sensorType":"Magnet","sensorMake":"Visonic Door/Window Contact","enrolled":true,"signalStrength":0,"lastEvent":false,"lastEventTime":0,"stat_doorOpen":false,"stat_bypased":false,"stat_lowBattery":false}
  • {"zoneId":1,"zoneName":"Puerta principal","zoneType":4,"zoneTypeStr":"Delay 1","sensorId":149,"sensorType":"Magnet","sensorMake":"Visonic Door/Window Contact","enrolled":true,"signalStrength":0,"lastEvent":true,"lastEventTime":55622,"stat_doorOpen":true,"stat_bypased":false,"stat_lowBattery":false}

powermax/zone<N>

Same payload as powermax/zone but published individually per zone (retained). Used by Home Assistant auto-discovery.

powermax/alarm_state

Home Assistant compatible alarm state string (retained).

  • disarmed / armed_home / armed_away / arming / pending / triggered

powermax/system

Send info about alarm event raised (armed, disarmed, raise alamr, who disarm, who arm..... sending in realtime event occurs)

  • {"event":"ARMED","whoArmed":0,"whoArmedStr":"System","armType":83,"armTypeStr":"Quick Arm Home"}
  • {"event":"DISARMED","whoDisarmed":39,"whoDisarmedStr":"User 1"}

powermax/command_ack

Acknowledgement published after each received command.

powermax/availability

LWT topic: online when ESP is connected, offline when it disconnects. Used by Home Assistant to mark entities unavailable.

INPUT TOPICS

powermax/command

Messages:

  • ARMHOME -> Raise arm home command into Powermax pannel
  • DISARM -> Raise disarm command into Powermax pannel
  • ARMAWAY -> Raise armaway command into Powermax pannel
  • REBOOT -> Reboot ESP8266
  • STATUS -> Force immediate publish of all status topics

Compilation

To import .zip libraries, in Arduino IDE, use Sketch->Include Library->Add Zip Library

About

PowerMax gateway ESP8266

Topics